Kentax UHV equipment  Price List   Downloads  E-Mail contact


Mini evaporator on a CF16 flange



The image show a Q5 point source with double shield on a CF16 flange (PS-CF16+PSQ5+PS2S).
Due to fast decay curve and low power consumption these arrangement works without shutter and cooling.
The length adapter allows adaptation to UHV systems of the user.

Point source on CF16 flange

Additional equipment to install a point source on a CF40 flange



The drawings show four CF40 flanges that can be used to mount all available point sources and shields in a simple way.
Length in UHV (flange - end of point source) is possible from 75mm to 300mm according to customer requirements.

Pictures for examples of the different variants can be found at the bottom of this page.
CF40 flangs with electrical feed through
CF40 flange (PS-CF40/H) flange with thermocouple type K and supply feed through, simple ring holder and internal plug.
CF40 flangs with electrical feed through
CF40 flange (PS-CF40/HC) with thermocouple type K, supply and cooling feed through and cooling tank holder and internal plug.
CF40 flangs with electrical feed through and CF16 flange
CF40 flange (PS-CF40/16HS) with thermocouple type K and supply feed through flange and CF16 flange (for shutter), simple ring holder and internal plug.
optional: shutter and rotary feed through with scale
CF40 flangs with electrical feed through and CF16 flange
CF40 flange (PS-CF40/16HCS) with thermocouple type K, supply and cooling feed through, CF16 flange (for shutter) and cooling tank holder and internal plug.
optional: shutter and rotary feed through with scale

Crucibles


Due to the very low degassing of quartz glass, we recommend
crucibles of this material for very pure preparation.
Aperture crucibles must be used if the evaporator/point source
is mounted horizontal or pointing downwards.
The aperture crucible can be used in head-down position
for the layer deposition on horizontal surface with masks.


Crucibles with and without aperture

Supply cable


Simple supply cable PS-ST for connecting the point source
to a power supply with a length of up to 4 m,
length according to customer requirements.


Supply cable PS-ST

Example to install point sources


one point sources on CF40 flange
The image shows the installation on the PS-CF40/H flange,
with the PS-Q5 (heating element) and a PS-2S (double shield).
The vacuum length is 90 mm.
point source on CF40 flange
The image shows the installation on the PS-CF40/H flange
with the PS-Q5 (heating element) and a PS-2S (double shield).
Due to the long length in the vacuum of 365 mm, the cable is routed internally
and the flange has three retaining bolts.


one point sources on CF40 flange
The image shows the installation on the PS-CF40/HS flange
with the PS-Q5 (heating element) and a PS-2S (double shield).
A rotary shutter (on CF16) can be added to this base flange.
point source on PS40-HCS
The image shows the installation on the PS-CF40/HCS flange
with the PS-Q5 (heating element) and a PS-2S (double shield).
This fully equipped evaporator has liquid cooling and a rotary shutter
(to be ordered in addition).

point sources on CF16 flange
The image shows the installation on the PS-CF16 flange
with the PS-Q5 (heating element) and a PS-2S (double shield).
The vacuum length is the minimum length of 92 mm.
connecting supply cable
The image one show connecting the supply cable
to the plug of the CF16 flange.


point sources heating
The image shows a point source evaporator in operation
at a temperature of 400°C.
point source heating high
The image shows a point source with double shielding
that is heated to a high temperature. The inner titanium shield glows,
while the outer stainless steel shield remains cool.